Dangerous Music Monitor
Analog Switching, D/A Conversion and Monitoring Functions
|
If you have a need for accurate monitoring of a variety of analog and digital signals, the Dangerous Monitor is a great choice. Sporting four AES/EBU digital inputs, and three analog stereo inputs, this 2U box also features Left and Right mutes, phase inverters, dim, and mono functions. It will control two pairs of monitors, and can be easily hooked up to analog and digital meters. The stepped output pot insures repeatability.
|
The Dangerous Monitor is an elegant integration of four distinct functions specifically designed to give you immediate and intuitive control, with the accuracy you need.
- Analog Input Switching
- Digital Input Switching
- Onboard D to A Conversion (Custom Designed by Troisi Designs, Ltd.)
- Comprehensive Monitoring Functions
The Monitor incorporates four distinct functions, seamlessly integrated into one 2 RU package:Analog switching, digital switching, on board D to A conversion, and comprehensive monitoring functions. It is designed to aid studio owners in their quest to access all of their equipment in a simple,intuitive way, while delivering the best sonic performance that money can buy.
- It Will Change the Way you Listen
- Superior Depth, Detail and Resolution
- Onboard D to A Conversion
- Seamless Switching Between Input Sources
The design team at Dangerous knows that while there are options for digital routing,conversion and analog switching available as stand-alone units, a system that integrates them in one package has not been available until now. The addition of comprehensive monitoring features -- along with stellar sound, unprecedented flexibility and ease of use -- makes the Dangerous Monitor an essential component of today's studio environment, and a perfect companion for the Dangerous 2-BUS.
Featuring:
- Analog input switching: 3 pairs of analog inputs
- Digital input switching: 4 digital inputs, with active thru outputs
- Onboard D/A: Custom Troisi converter
- Full console monitoring functions: L&R Phase reverse, L&R Mute, Mono, Dim, Alternate Speaker, and -6 VU Meter Offset
- Analog and digital meter feeds
- Stepped attenuator volume control for precise adjustment and repeatability
- Optional remote
Frequency Response: 1 Hz-100 kHz within 0.2 dB
Total Harmonic Distortion: 0.003% in audio band
Intermodulation Distortion: 0.002% IMD60 4:1
Converter Lock Range: 32 kHz - 96 kHz
Converter THD+Noise: 0.002%
Crosstalk @ 1 kHz: -113 dB
Crosstalk @ 10 kHz: -102 dB
Noise floor: -91 dBu total energy in audio band
Max level: +26 dBu
Nominal operating level: +4 dBu
Input impedance: 25k ohm balanced
Output impedance: 50 ohm balanced (600 ohm drive capable)
Gain accuracy: better than .05 dB @ 1 kHz for any gain setting
Power consumption: 40 watts
Size: 2 RU for Monitor, 1 RU for power supply
Warranty: 2 years parts and labor, subject to inspection. Does not include damage incurred through abusive operation or modifications/attempted repair by unauthorized technicians.
|
![]() |